3. SP Mode Tables
Col Drum Stop Time: Duty
009
Control
010 Correction Coefficient
Execution Temp. Threshold
011
Sets the temperature threshold to execute the printing Duty limitation.
0: Not execute
Cancellation Temp. Threshold
012
Sets the temperature threshold (differences with the temperature of the printing Duty
limitation execution) to cancel the printing Duty limitation.
ON/OFF setting
Control or not control the printing Duty limitation.
013
0: Not control
1: Control
176
*ENG
[0 to 65535 / 32000 / 10msec/step]
*ENG
[-1.0 to -1.0 / -0.5 / 0.1/step]
*ENG
[20.0 to 70.0 / 42.0 / 0.1deg/step]
*ENG
[0.0 to 20.0 / 1.0 / 0.1deg/step]
*ENG
[0 or 1 / 1 / 1/step]