Ricoh Aficio MP C305SP Field Service Manual page 1502

Gr-c1, machine codes: d117/d118
Hide thumbs Also See for Aficio MP C305SP:
Table of Contents

Advertisement

3. SP Mode Tables
CERT: Error
Displays a number code that describes the reason for the request for update of the
certification.
0
1
068
2
3
4
5
6
CERT:Up ID
069
The ID of the request for certification.
Firm Up Status
083
Displays the status of the firmware update
Firm Up User Check
This SP setting determines if the operator can confirm the previous version of the firmware
085
before the firmware update execution. If the option to confirm the previous version is
selected, a notification is sent to the system manager and the firmware update is done
with the firmware files from the URL.
Firmware Size
086
Allows the service technician to confirm the size of the firmware data files during the
firmware update execution.
318
Normal. There is no request for certification update in progress.
Request for certification update in progress. The current certification has expired.
An SSL error notification has been issued. Issued after the certification has
expired.
Notification of shift from a common authentication to an individual certification.
Notification of a common certification without ID2.
Notification that no certification was issued.
Notification that GW URL does not exist.
*CTL
[0 to 255 / 0 / 1/step]
*CTL
[- / - / -]
[0 to 5 / 0 / 1/step]
0: waiting for receiving firmware update.
1: waiting for scheduling firmware update
start.
*CTL
2: waiting for user confirmation
3: preparing for device firmware update.
4: processing device firmware update.
5: termination processing
*CTL
[- / - / -]
*CTL
[- / - / -]