011 Jam Detection: Time Length
Jam Detection: Continuous
012
Count
013 Door Open: Time Length
[SC/Alarm Setting]
5515
With @Remote in use, these SP codes can be set to issue an SC call when an SC error
occurs. If this SP is switched off, the SC call is not issued when an SC error occurs.
Sets the time a jam must remain before it
becomes an "unattended paper jam". This
setting is enabled only when SP5508-004
*CTL
is set to "1".
[3 to 30 / 10 / 1min./step]
Sets the number of consecutive paper jams
required to initiate a call. This setting is
enabled only when SP5508-004 is set to
*CTL
"1".
[2 to 10 / 5 / 1/step]
Sets the length of time the door remains
open before the machine initiates a call.
*CTL
This setting is enabled only when
SP5-508-004 is set to "1".
[3 to 30 / 10 / 1min./step]
*CTL
-
Main SP Tables-5
295