Ricoh Aficio MP C305SP Field Service Manual page 1508

Gr-c1, machine codes: d117/d118
Hide thumbs Also See for Aficio MP C305SP:
Table of Contents

Advertisement

3. SP Mode Tables
FAX TX Priority
187
This SP determines whether pushing the off-hook button will interrupt a RCG-M
transmission in progress to open the line for fax transaction. This SP can be used only if
SP5816 164 is set to "0".
200 Manual Polling
Regist Status
Displays a number that indicates the status of the @Remote service device.
0: Neither the registered device by the external nor embedded RCG device is set.
1: The embedded RCG device is being set. Only Box registration is completed. In this
status, this unit cannot answer a polling request from the external RCG.
201
2. The embedded RCG device is set. In this status, the external RCG unit cannot answer
a polling request.
3. The registered device by the external RCG is being set. In this status the embedded
RCG device cannot be set.
4 The registered module by the external RCG has not started.
Letter Number
202
Allows entering the number of the request needed for the RCG-N device.
Confirm Execute
203
Executes the inquiry request to the @Remote GW URL.
324
[0 or 1/ 0 / 1/step]
*CTL
0: Disable, 1: Enable
[0 or 1 / 0 / 1/step]
*CTL
0: Disable, 1: Enable
CTL
[0 to 4 / 0 / 1/step]
*CTL
[- / - / -]
[- / - / -]
CTL
[Execute]