3. SP Mode Tables
RCG Connect Timeout
008
Sets the length of time (seconds) for the time-out when the RCG (Remote Communication
Gate) connects during a call via the @Remote network.
RCG Write Timeout
009
Sets the length of time (seconds) for the time-out when sent data is written to the RCG
during a call over the @Remote network.
RCG Read Timeout
010
Sets the length of time (seconds) for the timeout when sent data is written from the RCG
during a call over the @Remote network.
Port 80 Enable
011
Controls if permission is given to get access to the SOAP method over Port 80 on the
@Remote network.
RFU Timing
013
Selects the timing for the remote firmware updating.
RCG Error Cause
014
Displays RCG connection error. cause
RCG-C Registed
021
This SP displays the RCG-N installation end flag.
314
*CTL
[1 to 90 / 30 / 1second/step]
*CTL
[0 to 100 / 60 / 1second/step]
*CTL
[0 to 100 / 60 / 1second/step]
[0 or 1 / 0 / 1/step]
*CTL
0: No. Access denied
1: Yes. Access granted.
[0 or 1 / 1 / 1/step]
*CTL
0: Any status of a target machine
1: Sleep or panel off mode only
[0 or 1 / 0 / 1/step]
CTL
0: Initial state, normal condition
1: Error
[0 or 1 / 0 / 1/step]
*CTL
0: Installation not completed
1: Installation completed