Parallel Input Matrix

EXTERNAL LOCK
AUTOMATIC
MANUAL
SERVO-CENTER
JOG LEFT *
JOG RIGHT *
RGPC LEFT *
RGPC RIGHT *
RGPC RESET *
SENSOR, EDGE L OR LINE CENTER **
SENSOR, EDGE R OR LINE EDGE **
SENSOR, EDGE CENTER **
* Inputs 4 & 5 are used to provide Jogs while in Manual and Servo Center modes, and
RGPC functions while in Automatic mode.
** Sensor selection is allowed in Manual and Servo Center modes, only. Sensor selection
must be momentary commands. For sensor selection, input 2 must be commanded either
simultaneously with, or prior to, inputs 1 & 3.
0 = LOW
1 = HIGH
- = IGNORE

Parallel Output Matrix

LOSS OF NULL (AUTOMATIC MODE)
CENTERED (SERVO-CENTER MODE)
* Parallel outputs are active low.
1 = ACTIVE
- = IGNORE
06-05-2007
DP-20 WEB GUIDE CONTROLLER USER MANUAL
MODE
STATUS
DP-20 WEB GUIDE CONTROLLER
7

PARALLEL MATRIX

INPUTS
5
4
3
-
-
-
-
-
0
-
-
0
-
-
1
0
1
-
1
0
-
0
1
-
1
0
-
1
1
-
-
-
0
-
-
1
-
-
1
OUTPUTS
B*
A*
-
1
1
-
7
7-1
2
1
0
-
-
1
0
1
-
1
0
-
0
0
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1
1
-
1
0
-
1
1
-
Figure Sheet 1-862-D