Siemens SIPROTEC 4 7UT6 Series Manual page 560

Differential protection
Table of Contents

Advertisement

Functions, Settings, Information
F.2 Settings
Addr. Parameter
836
SwitchgCBaux M1
837
SwitchgCBaux M2
838
SwitchgCBaux M3
839
SwitchgCBaux M4
840
SwitchgCBaux M5
841
SwitchgCBaux E1
851A
TMin TRIP CMD
901
WAVEFORM-
TRIGGER
903
MAX. LENGTH
904
PRE. TRIG. TIME
905
POST REC. TIME
906
BinIn CAPT.TIME
1107
P,Q sign
1111
PoleOpenCurr.S1
1112
PoleOpenCurr.S2
1113
PoleOpenCurr.S3
1114
PoleOpenCurr.S4
1115
PoleOpenCurr.S5
1121
PoleOpenCurr.M1
1122
PoleOpenCurr.M2
1123
PoleOpenCurr.M3
1124
PoleOpenCurr.M4
560
Function
C
Setting Options
P.System Data
(Einstellmöglich-
1
keiten anwendung-
sabhängig)
P.System Data
(Einstellmöglich-
1
keiten anwendung-
sabhängig)
P.System Data
(Einstellmöglich-
1
keiten anwendung-
sabhängig)
P.System Data
(Einstellmöglich-
1
keiten anwendung-
sabhängig)
P.System Data
(Einstellmöglich-
1
keiten anwendung-
sabhängig)
P.System Data
(Einstellmöglich-
1
keiten anwendung-
sabhängig)
P.System Data
0.01 .. 32.00 sec
1
Osc. Fault Rec.
Save w. Pickup
Save w. TRIP
Start w. TRIP
Osc. Fault Rec.
0.30 .. 5.00 sec
Osc. Fault Rec.
0.05 .. 0.50 sec
Osc. Fault Rec.
0.05 .. 0.50 sec
Osc. Fault Rec.
0.10 .. 5.00 sec; ∞
P.System Data
not reversed
2
reversed
P.System Data
0.04 .. 1.00 I/InS
2
P.System Data
0.04 .. 1.00 I/InS
2
P.System Data
0.04 .. 1.00 I/InS
2
P.System Data
0.04 .. 1.00 I/InS
2
P.System Data
0.04 .. 1.00 I/InS
2
P.System Data
1A
0.04 .. 1.00 A
2
5A
0.20 .. 5.00 A
P.System Data
1A
0.04 .. 1.00 A
2
5A
0.20 .. 5.00 A
P.System Data
1A
0.04 .. 1.00 A
2
5A
0.20 .. 5.00 A
P.System Data
1A
0.04 .. 1.00 A
2
5A
0.20 .. 5.00 A
Default Setting
Comments
none
Switchgear / CBaux at
Measuring Loc. M1
none
Switchgear / CBaux at
Measuring Loc. M2
none
Switchgear / CBaux at
Measuring Loc. M3
none
Switchgear / CBaux at
Measuring Loc. M4
none
Switchgear / CBaux at
Measuring Loc. M5
none
Switchgear / CBaux at ext.
location 1
0.15 sec
Minimum TRIP Command
Duration
Save w. Pickup
Waveform Capture
1.00 sec
Max. length of a Wave-
form Capture Record
0.20 sec
Captured Waveform Prior
to Trigger
0.10 sec
Captured Waveform after
Event
0.50 sec
Capture Time via Binary
Input
not reversed
sign of P,Q
0.10 I/InS
Pole Open Current
Threshold Side 1
0.10 I/InS
Pole Open Current
Threshold Side 2
0.16 I/InS
Pole Open Current
Threshold Side 3
0.16 I/InS
Pole Open Current
Threshold Side 4
0.16 I/InS
Pole Open Current
Threshold Side 5
0.04 A
Pole Open Current
Threshold Meas.Loc. M1
0.20 A
0.04 A
Pole Open Current
Threshold Meas.Loc. M2
0.20 A
0.04 A
Pole Open Current
Threshold Meas.Loc. M3
0.20 A
0.04 A
Pole Open Current
Threshold Meas.Loc. M4
0.20 A
SIPROTEC 4, 7UT6x, Manual
C53000-G1176-C230-5, Edition 09.2016