Siemens SIPROTEC 4 7UT6 Series Manual page 457

Differential protection
Table of Contents

Advertisement

NEG
Negator
NOR
NOR - Gate
OR
OR - Gate
REAL_TO_DINT
Real after DoubleInt, adapter
REAL_TO_UINT
Real after U-Int, adapter
RISE_DETECT
Rising edge detector
RS_FF
RS- Flipflop
RS_FF_MEMO
Status memory for restart
SI_GET_STATUS
Information status single point
indication, decoder
SI_SET_STATUS
Single point indication with
status, encoder
SQUARE_ROOT
Root Extractor
SR_FF
SR- Flipflop
SR_FF_MEMO
Status memory for restart
ST_AND
AND gate with status
ST_NOT
Negator with status
ST_OR
OR gate with status
SUB
Substraction
TIMER
Timer
TIMER_SHORT
Simple timer
UINT_TO_REAL
U-Int to real, adapter
UPPER_SETPOINT
Upper Limit
X_OR
XOR - Gate
ZERO_POINT
Zero Supression
General Limits
Designation
Maximum number of all CFC charts consid-
ering all task levels
Maximum number of all CFC charts consid-
ering one task level
Maximum number of all CFC inputs consid-
ering all charts
Maximum number of inputs of one chart
for each task level (number of unequal
information items of the left border per task
level)
Maximum number of reset-resistant flip-
flops
D_FF_MEMO
Device-specific Limits
Designation
Maximum number of synchronous changes
of chart inputs per task level
Maximum number of chart outputs per task
level
SIPROTEC 4, 7UT6x, Manual
C53000-G1176-C230-5, Edition 09.2016
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Limit
Comments
32
When the limit is exceeded, an error message is output by the
device. Consequently, the device is put into monitoring mode. The
red ERROR-LED lights up.
16
Only Error Message
(record in device fault log, evolving fault in processing procedure)
400
When the limit is exceeded, an error message is output by the
device. Consequently, the device is put into monitoring mode. The
red ERROR-LED lights up.
400
Only fault annunciation (record in device fault log); here the
number of elements of the left border per task level is counted.
Since the same information is indicated at the border several
times, only unequal information is to be counted.
350
When the limit is exceeded, an error message is output by the
device. Consequently, the device is put into monitoring mode. The
red ERROR-LED lights up.
Limit
Comments
50
When the limit is exceeded, an error message is output by the
device. Consequently, the device is put into monitoring mode. The
red ERROR-LED lights up.
150
4.20 User-defined Functions (CFC)
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Technical Data
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
457

Hide quick links: