Siemens SIPROTEC 4 7UT6 Series Manual page 544

Differential protection
Table of Contents

Advertisement

Functions, Settings, Information
F.2 Settings
Addr. Parameter
0
Func. assigned
0
Func. per phase
0
PICKUP WITH
0A
Type of meas.
0
FLEXIBLE FUNC.
0
Pick-up thresh.
0
Pick-up thresh.
0
Pick-up thresh.
0
Pick-up thresh.
0
Pick-up thresh.
0
Pick-up thresh.
0
Pick-up thresh.
0
Pick-up thresh.
544
Function
C
Setting Options
Flx
Please select
AuxiliaryCT IX1
AuxiliaryCT IX2
AuxiliaryCT IX3
AuxiliaryCT IX4
Flx
Please select
UL1E..UL3E
UL1E
UL2E
UL3E
UL12..UL31
UL12
UL23
UL31
U0 (Zero seq.)
U1 (Pos. seq.)
U2 (Neg. seq.)
U4/Uen
Flx
Exceeding
Dropping below
Flx
accurate
fast
Flx
OFF
ON
Alarm Only
Block relay
Flx
1A
0.05 .. 35.00 A
5A
0.25 .. 175.00 A
Flx
1A
0.05 .. 35.00 A
5A
0.25 .. 175.00 A
Flx
1A
0.05 .. 35.00 A
5A
0.25 .. 175.00 A
Flx
1A
0.05 .. 35.00 A
5A
0.25 .. 175.00 A
Flx
1A
0.05 .. 35.00 A
5A
0.25 .. 175.00 A
Flx
1A
0.05 .. 35.00 A
5A
0.25 .. 175.00 A
0.1
0.005 .. 3.500 A
A
Flx
1A
0.05 .. 35.00 A
5A
0.25 .. 175.00 A
0.1
0.005 .. 3.500 A
A
Flx
1A
0.05 .. 35.00 A
5A
0.25 .. 175.00 A
0.1
0.005 .. 3.500 A
A
Default Setting
Comments
Please select
Function is applied to
Please select
Function utilises compo-
nent(s)
Exceeding
Pickup with
accurate
Selection of type of meas-
urement
OFF
Flexible Function
2.00 A
Pick-up threshold I meas.
location 1
10.00 A
2.00 A
Pick-up threshold I meas.
location 2
10.00 A
2.00 A
Pick-up threshold I meas.
location 3
10.00 A
2.00 A
Pick-up threshold I meas.
location 4
10.00 A
2.00 A
Pick-up threshold I meas.
location 5
10.00 A
2.00 A
Pick-up threshold I1
10.00 A
0.200 A
2.00 A
Pick-up threshold I2
10.00 A
0.200 A
2.00 A
Pick-up threshold I3
10.00 A
0.200 A
SIPROTEC 4, 7UT6x, Manual
C53000-G1176-C230-5, Edition 09.2016