5.2 Modes

Mode
RUN mode
Monitor mode
Initial setting mode
Main setting mode
Sub setting mode
Engineering mode 1
Engineering mode 2
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
When power is turned ON, the unit enters RUN mode.
The PV Display indicates PV, and the SV Display indicates SV.
Control starts from previous status (last shutdown).
By pressing the
key for approx. 1 sec, one of the following functions
selected in [OUT/OFF key function] is activated.
OUT/OFF Key Function
Control output OFF function
Auto/Manual control
Program control
By pressing the
key for approx. 3 sec in RUN mode, the unit enters
Monitor mode. The PV Display indicates PV, and the SV Display indicates MV.
Every time the
key is pressed, the following is indicated.
Indicated contents differ depending on the model number.
Model number
KT4R
Indicates MV, Remaining time (Program control) or
Step number (Program control).
KT8R, KT9R
Indicates MV or Remaining time (Program control).
By pressing the
and
RUN mode, the unit enters Initial setting mode.
The following items can be set:
Input type, Scaling high limit/low limit, Event output EV1/EV2 allocation,
SV1, etc.
By pressing the
key in RUN mode, the unit enters Main setting mode.
SV can be set.
If 'Program control' is selected in [OUT/OFF key function], SV, Time and Wait
value for Steps 1 to 9 can be set.
By pressing the
and
unit enters Sub setting mode.
The following items can be set:
AT Perform, P, I, D, Direct/Reverse action, Event output EV1/EV2, etc.
By pressing the
and
RUN mode, the unit enters Engineering mode 1.
The following items can be set:
Set value lock, Event output EV1/EV2 allocation, Sensor correction,
PV filter time constant, Program control, OUT/OFF key function,
Controller/Converter, etc.
By pressing the
,
RUN mode, the unit enters Engineering mode 2.
The following items can be set:
Control method, Proportional gain 2DOF coefficient (α), Integral 2DOF
coefficient (β)
Description
Turns the control output ON or OFF.
Switches the Auto/Manual control.
Starts/Stops the Program control.
Indicated Contents
keys (in that order) together for approx. 3 sec in
keys (in that order) together in RUN mode, the
keys (in that order) together for approx. 3 sec in
,
keys (in that order) together for approx. 5 sec in
Description