Rush current
Ambient temperature
Ambient humidity
Weight
KT4R
KT8R
KT9R
Accessories included
Accessories sold
separately
Environmental specification
Attached Functions
Sensor correction
coefficient
Sensor correction
Set value lock
Auto/Manual control
switching
Balanceless-bumpless
function
SV ramp function
SV Rise/Fall rate start type
Program control
Power failure
countermeasure
Self-diagnosis
Automatic cold junction
temperature compensation
Indication
Thermocouple
range,
Control
RTD
range
DC voltage,
Direct current
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
100 to 240 V AC
Max. 14 to 34 A
24 V AC
Max. 34 A
24 V DC
Max. 34 A
(*) 24 V AC/DC can be specified only for the KT4R model.
-10 to 55
(Non-condensing, No icing)
35 to 85%RH (Non-condensing)
Approx. 110 g
Approx. 160 g
Approx. 220 g
Mounting frame: 1 piece (KT4R)
Screw type mounting bracket: 1 set (KT8R, KT9R)
Installation Instructions (excerpt): 1 copy
Terminal cover
RoHS directive compliant
Sets slope of input value from a sensor.
Corrects the input value from a sensor.
Locks the set values to prevent setting errors.
Switches Auto/Manual control.
In Manual control, sets MV with the
When control is changed from automatic to manual and vice versa, the
balanceless-bumpless function works to prevent sudden change of the
MV.
When the SV is adjusted, it approaches the new SV by the preset
rate-of-change. Set SV rise rate and SV fall rate respectively.
When control output is turned from OFF to ON, or switched from Manual
to Automatic control, SV start or PV start can be selected for SV rise rate
or fall rate action.
1 pattern; 9 steps
The setting data is backed up in the non-volatile IC memory.
The CPU is monitored by a watchdog timer, and if an abnormal status
occurs, the controller is switched to warm-up status, turning all outputs
OFF.
This detects the temperature at the connecting terminal between the
thermocouple and the instrument, and always maintains it at the same
status as if the reference junction location temperature was at 0
[Input range low limit value - 50
[Input range high limit value + 50
[Input range low limit value – (Input span x 1%)] to
[Input range high limit value + 50
[Scaling low limit value – (Scaling span x 1%)] to
[Scaling high limit value + Scaling span x 10%]
(*)
(*)
or
key.
(100 )] to
(100 )]
(100 )]
(32 ).