Panasonic KT4R User Manual page 59

Kt series temperature controller
Hide thumbs Also See for KT4R:
Table of Contents

Advertisement

Characters,
Factory Default
[D]
EV2 alarm hysteresis
• Sets EV2 alarm hysteresis.
Corresponds to [EV2 alarm hysteresis] in Initial setting mode.
• Setting range: 0.1 to 1000.0
DC voltage, current inputs: 1 to 10000
Available only when Event output EV2 is specified.
Available when any alarm from
limits with standby independent alarm) is selected in [Event output EV2 allocation].
[E]
EV2 alarm delay time
• Sets EV2 alarm action delay time.
Corresponds to [EV2 alarm delay time] in Initial setting mode.
When setting time has elapsed after the input enters the alarm output range, the
alarm is activated.
• Setting range: 0 to 10000 seconds
Available only when Event output EV2 is specified.
Available when any alarm from
limits with standby independent alarm) is selected in [Event output EV2 allocation].
[F]
EV2 alarm Energized/De-energized
• Selects Energized/De-energized status for EV2 alarm.
Corresponds to [EV2 alarm Energized/De-energized] in Initial setting mode.
Refer to 'EV1/EV2 Energized/De-energized' (p.40).
• Selection item:
Available only when Event output EV2 is specified.
Available when any alarm from
limits with standby independent alarm) is selected in [Event output EV2 allocation].
[G]
TS2 output step number
• Sets the step number for which Time signal output TS2 is turned OFF or ON
during Program control.
Corresponds to [TS2 output step number] in Initial setting mode.
• Setting range: 1 to 9
Available only when
[H]
TS2 OFF time
• Sets Time signal output TS2 OFF time.
Corresponds to [TS2 OFF time] in Initial setting mode.
• Setting range: 00:00 to 99:59
Available only when
[I]
TS2 ON time
• Sets Time signal output TS2 ON time.
Corresponds to [TS2 ON time] in Initial setting mode.
• Setting range: 00:00 to 99:59
Available only when
(*1) The placement of the decimal point follows the selection.
(*4) Time unit follows the selection from [Step time unit].
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Setting Item, Function, Setting Range
( ),
(Alarm output, High limit alarm) to
(Alarm output, High limit alarm) to
Energized
De-energized
(Alarm output, High limit alarm) to
(Time signal output) is selected in [Event output EV2 allocation].
(*4)
(Time signal output) is selected in [Event output EV2 allocation].
(*4)
(Time signal output) is selected in [Event output EV2 allocation].
(*1)
(Alarm output, High/Low
(Alarm output, High/Low
(Alarm output, High/Low

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kt9rKt8r

Table of Contents