Panasonic KT4R User Manual page 44

Kt series temperature controller
Hide thumbs Also See for KT4R:
Table of Contents

Advertisement

Characters,
Factory Default
[19]
SV4
• Sets SV4.
• Corresponds to [SV4] in Initial setting mode.
If Program control is selected in [OUT/OFF key function], this will become Step 4
SV.
• Setting range: Scaling low limit to Scaling high limit
Available only when Program control is selected in [OUT/OFF key function].
Step 4 time
[20]
• Sets Step 4 time.
• Setting range:
If
using Step 4 SV.
Available only when Program control is selected in [OUT/OFF key function].
[21]
Step 4 wait value
• Sets Step 4 wait value.
• Setting range: 0 to Converted value of 20% of the input span
DC voltage, current inputs: 0 to Converted value of 20% of scaling span
Setting the value to 0 disables Wait function.
Available only when Program control is selected in [OUT/OFF key function].
[22]
Step 5 SV
• Sets Step 5 SV.
• Setting range: Scaling low limit to Scaling high limit
Available only when Program control is selected in [OUT/OFF key function].
Step 5 time
[23]
• Sets Step 5 time.
• Setting range:
If
using Step 5 SV.
Available only when Program control is selected in [OUT/OFF key function].
[24]
Step 5 wait value
• Sets Step 5 wait value.
• Setting range: 0 to Converted value of 20% of the input span
DC voltage, current inputs: 0 to Converted value of 20% of scaling span
Setting the value to 0 disables Wait function.
Available only when Program control is selected in [OUT/OFF key function].
(*1) The placement of the decimal point follows the selection.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Setting Item, Function, Setting Range
, or 00:00 to 99:59
is set, Step 4 time will be held, and Fixed value control will be performed
, or 00:00 to 99:59
is set, Step 5 time will be held, and Fixed value control will be performed
(*1)
(*1)
(*1)
(*1)

Hide quick links: