Pressure profile

Set the pressure profile data specified by the pressure profile start device in order to perform feed/dwell operation.
Setting pressure profile data
Pressure profile data can be set with a Motion SFC program, or with MT Developer2.
■Setting with Motion SFC program
Write the values directly from the Motion SFC program to the devices on or after the pressure profile start device set in the
pressure control data.
■Setting with MT Developer2
Write the devices in the pressure profile test of MT Developer2.
Refer to the following for details of operation method.
Help of MT Developer2
[Online]  [Pressure profile test]
The profile data set in the pressure profile test is not saved to the project. In order to enable profile data when
starting up the Motion CPU, perform the following.
• Set the device area of devices set by the pressure profile data to the latch range.
• Create a Motion SFC program to set pressure profile data.
7 AUXILIARY AND APPLIED FUNCTIONS
7.7 Pressure Control
7
453