Override Data; Override Ratio Setting Device - Mitsubishi Electric MELSEC iQ-R16MTCPU Programming Manual

Melsec iq-r series, positioning control
Hide thumbs Also See for MELSEC iQ-R16MTCPU:
Table of Contents

Advertisement

3.10

Override Data

Override data is for using the override function.
[Motion Control Parameter]  [Axis Setting Parameter]  "Override Data"
No. Item
1
Override ratio setting
*2
device
*1 Refer to the indirect setting method by devices for parameters for the range of devices used for indirect setting. (Page 168 Indirect
Setting Method by Devices for Parameters)
*2 This setting can be omitted.

Override ratio setting device

Set the device that sets the override ratio of the override function.
Set override ratio setting device to the override ratio values below.
Refer to override function for details of the override ratio setting device. (Page 462 Override Function)
Override ratio
-1
0 to 3000(10
[%])
3 PARAMETERS FOR POSITIONING CONTROL
210
3.10 Override Data
Default
Setting range
value
mm
inch
Direct
setting
degree
pulse
Valid/
invalid
*1
Indirect setting
Reference
Section
Valid/
Fetch
invalid
cycle
(Required
size)
Operation
Page
(1 word)
cycle
210