Monitor CLI Commands
repeat repeat — Configures how many times the command is repeated.
absolute — When the absolute keyword is specified, the raw statistics are displayed, without pro-
cessing. No calculations are performed on the delta or rate statistics.
rate — When the rate keyword is specified, the rate-per-second for each statistic is displayed instead
Sample Output
A:ALA-48# monitor filter ipv6 100 entry 10 interval 3 repeat 3 absolute
===============================================================================
Monitor statistics for IPv6 filter 100 entry 10
===============================================================================
-------------------------------------------------------------------------------
At time t = 0 sec (Base Statistics)
-------------------------------------------------------------------------------
Ing. Matches : 0
-------------------------------------------------------------------------------
At time t = 3 sec (Mode: Absolute)
-------------------------------------------------------------------------------
Ing. Matches : 0
-------------------------------------------------------------------------------
At time t = 6 sec (Mode: Absolute)
-------------------------------------------------------------------------------
Ing. Matches : 0
-------------------------------------------------------------------------------
At time t = 9 sec (Mode: Absolute)
-------------------------------------------------------------------------------
Ing. Matches : 0
===============================================================================
A:ALA-48#
A:ALA-48# monitor filter ipv6 100 entry 10 interval 3 repeat 3 rate
==============================================================================
Monitor statistics for IPv6 filter 100 entry 10
==============================================================================
------------------------------------------------------------------------------
At time t = 0 sec (Base Statistics)
------------------------------------------------------------------------------
Ing. Matches : 0
------------------------------------------------------------------------------
At time t = 3 sec (Mode: Rate)
------------------------------------------------------------------------------
Ing. Matches : 0
------------------------------------------------------------------------------
Page 66
Default
5 seconds
Values
3 — 60
Default
10
Values
1 — 999
of the delta.
7710 SR OS Basic System Configuration Guide
Egr. Matches
: 1
Egr. Matches
: 1
Egr. Matches
: 1
Egr. Matches
: 01
Egr. Matches
: 1
Egr. Matches
: 1