Alcatel-Lucent 7710 SR Configuration Manual page 64

Service router os basic system
Hide thumbs Also See for 7710 SR:
Table of Contents

Advertisement

Monitor CLI Commands
ip
Syntax
ip ip-filter-id entry entry-id [interval seconds] [repeat repeat] [absolute | rate]
Context
monitor>filter
Description
This command enables IP filter monitoring. The statistical information for the specified IP filter entry
displays at the configured interval until the configured count is reached.
The first screen displays the current statistics related to the specified IP filter. The subsequent
statistical information listed for each interval is displayed as a delta to the previous display.
When the keyword rate is specified, the "rate per second" for each statistic is displayed instead of the
delta.
Monitor commands are similar to show commands but only statistical information displays. Monitor
commands display the selected statistics according to the configured number of times at the interval
specified.
Parameters
ip-filter-id — Displays detailed information for the specified filter ID and its filter entries.
entry entry-id — Displays information on the specified filter entry ID for the specified filter ID only.
interval seconds — Configures the interval for each display in seconds.
repeat repeat — Configures how many times the command is repeated.
absolute — When the absolute keyword is specified, the raw statistics are displayed, without
rate — When the rate keyword is specified, the rate-per-second for each statistic is displayed
Sample Output
A:ALA-1>monitor# filter ip 10 entry 1 interval 3 repeat 3 absolute
===============================================================================
Monitor statistics for IP filter 10 entry 1
===============================================================================
At time t = 0 sec (Base Statistics)
-------------------------------------------------------------------------------
Ing. Matches: 0
-------------------------------------------------------------------------------
At time t = 3 sec (Mode: Absolute)
-------------------------------------------------------------------------------
Ing. Matches: 0
-------------------------------------------------------------------------------
At time t = 6 sec (Mode: Absolute)
-------------------------------------------------------------------------------
Ing. Matches: 0
-------------------------------------------------------------------------------
Page 64
Values
1 — 65535
Values
1 — 65535
Default
5 seconds
Values
3 — 60
Default
10
Values
1 — 999
processing. No calculations are performed on the delta or rate statistics.
instead of the delta.
7710 SR OS Basic System Configuration Guide
Egr. Matches
: 0
Egr. Matches
: 0
Egr. Matches
: 0

Advertisement

Table of Contents
loading

Table of Contents