SAGEM-LINK F
Installation and Operation Manual
Cable Interface Module LEDs
•
The "Modem" alarm LED lights red, when there is a cable interface module alarm like a
modulator fault, a demodulator fault (receive data not recovered), or a power supply fault. This
alarm is red if the ODU is not connected.
•
The "RSL" alarm LED lights red, when the current receive signal level is below the RSL
threshold, or when there is a BER degradation (BER alarm, or BER warning active). This alarm
corresponds in most cases to a propagation or to an interferer problem
•
The "ODU" alarm LED lights red, if there is an ODU alarm, or if there is an ODU not connected.
•
The "Power" Status indication lights green, when Cable Interface Module is powered.
4.5 - SAGEM-LINK F Pilot Alarm Menus
SAGEM-LINK F Pilot software provides information on link status and alarm information. These
informations are available in the main screen and in the alarm menu. Refer to chapter 3 for Pilot
description
4.5.1 – Alarms Screen
Click on the alarm menu (refer to chapter 3 section 3.3.2 for description). Click on the "All alarms" tab
to have a complete view of all available alarms (local or remote terminal). All active alarms are
indicated with a red color.
The description of all available SAGEM-LINK F alarms is given below :
ODU Alarms
ODU PSU
Reproduction and communication prohibited without the written permission of Sagem Communication
Description
Power Supply Alarm returned from the ODU. This
alarm is active when there is a default in the ODU
Corrective action
Check DC Power supply, and cable
losses. If the cable and DC power are
Page 99/142
Issue 04 : July 2005