Clear the counter, and verify there is no error occurred during one minute.
If a revertive switch is used, from the local terminal select "Auto" for both transmitter and receiver.
Main local ODU should be now active.
If there is no revertive switch selected, select Rx1 and Tx1 in manual mode and validate. Then click on
the "Auto" cases.
The system is now in automatic mode, and the maintenance LED should be off.
Note : During transmitter switch from standby to main, errors are also generated.
Use the same procedure from the remote end of the link.
Reproduction and communication prohibited without the written permission of Sagem Communication
Tx Main (L)
Rx Main (L)
Tx Standby (L)
Rx Standby (L)
Figure 2.4 : Standby local transmitter and receiver active
288055571-04
Tx Main (R)
Rx Main (R)
Tx Standby (R)
Rx Standby (R)
Page 42/142
Issue 04 : July 2005