Alarms Description
ODU Alarms
ODU PSU : Power Supply Alarm returned from the ODU. This alarm is active when there is a
ODU Cable : ODU Cable Alarm is generated by the ODU in case of a transmit IF level below
Transmit Power : A transmit Power alarm is generated by the ODU in case of a transmitter
Transmit Frequency : This alarm is generated in case of IF or RF transmit synthesizer faults.
Receive Frequency : This alarm is generated in case of IF or RF receive synthesizer faults.
Receive Level : This alarm is generated when receive signal level is below the receive
Tributary Alarms : a tributary alarm is generated when there is a lack of input signal for a tributary
IDU Alarms
Warning 1+1 : A 1+1 warning is generated when the main or the standby units (ODU or cable
ID Code : When local and remote ID Code do not match, there is an ID Code alarm generated,
IDU : This alarm is active in case of an IDU fault, or in case of problem to recover receive data.
BER Warning : This warning is generated when BER is greater than the BER warning
BER Alarm : This alarm is generated when BER is greater than the BER alarm threshold
Local Aux In Alarms : These alarms represent local terminal input dry loop status.
Remote Aux In Alarms : These alarms represent remote terminal input dry loop status.
Reproduction and communication prohibited without the written permission of Sagem Communication
default in the ODU power supply, or when the DC input voltage at ODU input is too
low. In case of an ODU alarm, check DC Power supply, and cable losses.
the limit. In case of an ODU Cable alarm, check IDU to ODU cable losses.
AGC loop fault, or in case of a transmitter mute set by the operator (in 1+1 system
when both transmitters are in mute position)
When this alarm is active, transmitter is also in mute position.
threshold (default -70 dBm).
configured as "normal" (N), or when there is a input signal for a tributary configured as
"inverted" (I). In case of a tributary alarm, check the corresponding cable, and verify
that external equipment is properly connected.
interface module) is not working properly (alarm or absent).
and there is a AIS emission on the receive data from the remote terminal. To clear this
alarm change the ID Code on one terminal.
-6
threshold (default 10
)
-3
(default 10
)
288055571-04
Page 69/142
Issue 04 : July 2005