64 kbit/s Auxiliary Data Channel (AUX3)
The 64 kbit/s auxiliary data channel connector "AUX3" is available in a DB 15 connector on the rear
panel.
This data channel can be configured in a V11 co-directional mode (transmit clock given by the
external equipment) or in a V11 contra-directional mode (transmit clock given by SAGEM LINK F) :
Aux3 Connector pinout is given in Figure 1.24
Reproduction and communication prohibited without the written permission of Sagem Communication
8
15
Pin #
I/O
1
I
Byte Timing Input (-)
9
I
Transmit Data Input (-)
2
I
Byte Timing Input (+)
10
I/O
Transmit Clock (-)
3
O
Byte Timing Output (-)
11
I/O
Transmit Clock (+)
4
O
Receive Data (+)
12
O
Receive Clock (+)
5
O
Receive Data (-)
13
O
Receive Clock (-)
6
O
Byte Timing Output (+)
14
-
Ground
7
-
Ground
15
-
NC
8
I
Transmit Data Input (+)
Figure 1.24 – Aux3 Data Channel Connector Pinout