The BER tester shall be configured as follows :
2 Mbit/s data rate, HDB3, with a 2
in the IDU.
Run the test for the required amount of time
Depending on the BER tester used, results could be transferred electronically to the PC via
a serial port in a file. If it is not possible, the results shall be printed on paper.
Once all these tests have been completed, do not forget to remove tributary daisy chain arrangement.
The system is now ready to operate with traffic connected. If any test have failed to meet specifications,
consult the troubleshooting chapter in this manual.

2.10 - Recording Configuration Information

This procedure explain how to get all necessary information from SAGEM LINK F equipment to be
attached with Sagem Link F Field Commissioning Form.
Connect the computer to the local IDU and run the Sagem Link F Pilot software in super user mode
(default password : "2345")
Link Configuration Information :
From the main screen, open the menu "Configuration/Print", this screen appears :
Validate
Save the file in the PC using a name including site names :
Reproduction and communication prohibited without the written permission of Sagem Communication
Figure 2.6 : Tributary daisy chain connections
15
-1 sequence, using the same impedance than selected
Check all cases
Select File
288055571-04