NMI Card Configuration – Ports Tab
Click on the "Ports" tab : The following screen appears :
The screen is divided in four sections :
Ethernet Link section : enter the IP address and submask of the Ethernet link and check the case
"ON" to activate the port.
TSL2 section : TSL2 corresponds to a SAGEM-LINK F data channel dedicated to carry management
data between local and remote NMI.
TSL2 is a serial link with a local IP address on the local terminal and a Peer IP address on the remote
end terminal. If TSL2 link is involved for this equipment, it is necessary to enter both IP addresses,
and to check the "ON" case for Administration status.
When TSL2 port is not used (i.e. there is no management specific link between the two terminals of
the link) check the "OFF" case
Operational status : this information gives an information on the TSL2 link status between local NMI
interface and remote NMI interface.
MGMT1 and MGMT2 sections : MGMT1 and MGMT2 corresponds to two serial ports used to
connect two equipments or to connect the NMI to an external equipment (modem).
When these ports are not used, click on the "OFF" case on the corresponding administration status
line.
If they are used, then enter port IP address, subnet mask and choose interface and communication
protocol (default : PPP).