Sagem -LINK F Installation And Operation Manual page 72

Microwave radio links 7 ghz - 38 ghz
Table of Contents

Advertisement

SAGEM-LINK F
Installation and Operation Manual
Cable 2
Modulation 1
Modulation 2
Demodulation 1
Demodulation 2
Link ID Code
IDU
BER Warning
BER Alarm
Local Aux Input k
Remote Aux Input n
Tributary i Fault
Measurements List
RSL Channel 1 - xx dBm
RSL Channel 2 - xx dBm
BER Channel 1 nE-m
BER Channel 2 nE-m
G.821 Quality Data
Period 1mn/15mn/30mn/60mn/24h
G821 – ES
G821 – IS
G821 - SES xx
G821 - IP
G821 - ESR xx %
G821 - SESR xx %
G821 - ISR
G.826 Quality Data
Period 1mn/15mn/30mn/60mn/24h
G826 - ES
G826 - SES xx
G826 - BBE xx
G826 - ESR xx %
G826 - SESR xx %
G826 - BBER xx %
Events that may occur during monitoring
LOCAL-REMOTE(TSL) Broken/Restored : radio link broken/restored,
IDU-ODU(DCC)
TRANSMISSION Channel 1/Channel 2
RECEPTION
The connection with SAGEM-LINK F
Equipment is broken / restarted
3.3.3.2 - Edit Monitor List
When Clicking on the Edit Monitor List menu, the following screen appears :
Reproduction and communication prohibited without the written permission of Sagem Communication
: ODU Cable alarm 2 (standby)
: Modulator alarm on channel 1 (main)
: Modulator alarm on channel 2 (standby)
: Demodulator alarm on channel 1 (main)
: Demodulator alarm on channel 2 (standby)
: Link ID Code alarm
: IDU alarm
: Alarm on auxiliary input k on local equipment (k = 1 to 4)
: Alarm on auxiliary input n on remote equipment (n = 1 to 4)
: Alarm on tributary i (i= 1 to 16)
: RSL on channel 1 (main) equal to - xx dBm
: RSL on channel 2 (standby) equal to - xx dBm
: Bit error rate on channel 1 equal to nx10
: Bit error rate on channel 2 equal to nx10
xx
xx
xx
xx %
xx
Broken/Restored
Channel 1/Channel 2
: G.821 data measuring period
: number of errored seconds
: number of unavailable seconds
: number of seriously errored seconds
: number of unavailable periods
: rate of errored seconds over the measuring period (indicated
above)
: rate of seriously errored seconds over the measuring period
(indicated above)
: rate of unavailable seconds over the measuring period
(indicated above)
: G.826 data measuring period
: number of errored seconds
: number of seriously errored seconds
: number of residual errored blocks, i.e. errored blocks coming
outside the seriously errored seconds (SES)
: rate of errored seconds over the measuring period (indicated
above)
: rate of seriously errored seconds over the measuring period
(indicated above)
: rate of residual errored blocks over the measuring period
(indicated above)
: Communication link between IDU and ODU broken/restored,
: channel 1/channel 2 radio transmitter switch,
: channel 1/channel 2 radio receiver switch,
: PC does not communicate with equipment any
more
288055571-04
-m
-m
Page 72/142
Issue 04 : July 2005