Sagem -LINK F Installation And Operation Manual page 31

Microwave radio links 7 ghz - 38 ghz
Table of Contents

Advertisement

SAGEM-LINK F
Installation and Operation Manual
9600 bit/s Auxiliary Data Channel (AUX1 & Aux2)
The 9600 bit/s auxiliary data channels "AUX1" and AUX2 are connected to two DB 9 connectors on
the rear panel.
This data channels can be configured either in a DCE V11 interface, or V28 interface (compliant to
EIA 574 standard). Depending on the interface, connector pinout is given on Figure 1.25
Pin #
1
2
3
4
5
Serial Management Interface Ports MGMT1 and MGMT2
Serial management interface ports MGMT1 and MGMT2 are available in two DB25 connectors located
on the rear panel.
Data rate available : 9600 bit/s up to 115200 bit/s.
MGMT1 port can be configured in two modes :
- V11 synchronous mode (EIA 530)
- V28 asynchronous mode (ISO 2110)
MGMT1 port can be connected to a modem (RTS, CTS, DTR, DSR and DCD available).
MGMT2 port is not configurable, and is only available in V11 synchronous mode and X24/V11. When it
is used in X24 mode, this interface is a DCE type (terminal mode).
Connector pinout is given in Figure 1.26
Reproduction and communication prohibited without the written permission of Sagem Communication
V11 Interface
Ground
6 NC
Output Data – (+)
7 Output Data – (-)
Input Data – (+)
8 Input Data – (-)
NC
9 NC
Ground
Figure 1.25 – Aux1 or Aux2 Data Channel Connector Pinout
5
1
9
6
V28 Interface
Ground
NC
Output Data
NC
Input Data
NC
NC
NC
Ground
288055571-04
Page 31/142
Issue 04 : July 2005