Extron electronics XTP CrossPoint1600 User Manual page 114

Xtp crosspoint series configurable digital video matrix switchers
Table of Contents

Advertisement

Command Function
Outputs on XTP CP 4o [XTP], XTP CP 4o 4K [XTP], and XTP CP 4o Fiber 4K Boards (continued)
Ethernet serial port insert parameters (continued)
Set UART starting point
NOTE: Output insert port 1 is 32 positions from
Read UART starting point
Outputs on XTP CP 4o [XTP] and XTP CP 4o 4K [XTP] Boards
XTP power
ATTENTION:
Power over XTP (PoX) is intended for indoors use only. No part of a network that uses PoX can be routed outdoors.
PoX est destiné à une utilisation en intérieur uniquement. Aucune partie d'un réseau qui utilise PoX ne peut être routée en extérieur.
NOTES:
PoX is supplied by the matrix switcher 48 V power supply.
XTP CrossPoint 1600:
Can power up to 28 total (input and output) endpoints at up to 364 watts.
Is available with optional 48 V power supply redundancy.
XTP CrossPoint 3200:
Can power up to 24 total (input and output) endpoints at up to 312 watts.
No 48 V power supply redundancy is available.
Enable or disable power to output
endpoint and report status
View output power status
Enable or disable output power and
report status, all outputs
View all output power status
View XTP power usage
:
NOTE
X@
= Output number
X2!
= UART starting point
X2@
= Enable or disable for power
X2#
= Amount of power requested
X2$
= Power status
X2%
= Wattage
X2^
= Power supply status
SIS Command
Response
(Host to Unit)
(Unit to Host)
EX2!
}
MD
Pmd
X2!
for both 1600 and 3200 matrix sizes.
E
}
X2!]
MD
E
X@
X2@
}
O
*
POEC
PoecO
E
X@
}
X2@
O
POEC
E
X2@
}
O
*POEC
PoecO00*
E
}
X2@
OPOEC
E
}
X2%
TPOEC
01
16 or 32
The starting point (
X2!
) is the rear panel RS-232/RS-422 port.
The next position (
X2!
+1
For the XTP CrossPoint 1600,
For the XTP CrossPoint 3200,
For the XTP CrossPoint 1600 —
For the XTP CrossPoint 3200 —
Default values:
1999
2001
2001
2033
2033
= Disable (default)
0
or
(watts)
00
13
= Unpowered endpoint
0
= Power provided to endpoint
1
Power usage in 0.1 watt increments. Example: 260 = 26.0 watts
= Ok
0
Additional Description
X2!]
Sets the initial (lowest) port number for the
range of numbers assigned to the serial
port and UARTs.
X@
X2@
X2#
X2$]
Enable or disable (
*
*
*
output
X2#
watts and the power status is
X2#
X2$]
*
*
X2@
X2@
X2@
]
X2@
...
Each
1
2
n
an output, starting at 1. n is
X2@
X2@
X2@
]
1
2
3
...
n
X2^]
Show PoX wattage applied and the
*
status of the 48 V power supply.
) is not used.
X2!
+2
through
X2!
+17
are XTP inputs.
X2!
through
X2!
are XTP inputs.
+2
+33
X2!
X2!
through
are XTP outputs.
+18
+34
X2!
X2!
through
are XTP outputs.
+34
+65
= Rear panel remote RS-232/RS-422 port
through
2016
(XTP CrossPoint 1600) = Inputs
through
2032
(XTP CrossPoint 3200) = Inputs
through
(XTP CrossPoint 1600) = Output 1 through 16
2048
through
(XTP CrossPoint 3200) = Output 1 through 32
2064
= Enable
1
= Power available but disabled
2
= No power available, but enabled
3
= Not Ok
1
XTP CrossPoint Series • Programming Guide
X2@
) remote power on
X@
. The endpoint is requesting
X2$
.
is the enable or disable status of
.
16 or 32
= Fault
4
106

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xtp crosspoint 3200

Table of Contents