Sflow Sampler Settings - D-Link xStack DGS-3400 Series Reference Manual

Web ui reference guide for layer 2+ managed gigabit ethernet switch
Hide thumbs Also See for xStack DGS-3400 Series:
Table of Contents

Advertisement

x Stack
The following fields can be configured or viewed:
Parameter
Analyzer Server (1-
4)
Owner
Timeout (1-2000000
sec)
Collector IPv4
Address
Collector IPv6
Address
Collector Port (1-
65535)
Max Datagram Size
(300-1400)
Click Apply to save the changes.

sFlow Sampler Settings

This window will allow users to configure the Switch's settings for taking sample packets from the network, including the
sampling rate and the amount of the packet header to be extracted.
®
DGS-3400 Series Layer 2 Gigabit Ethernet M anaged Sw itch
Figure 2 - 139 sFlow Analyzer Settings – Edit window
Description
Enter an integer from 1 to 4 to denote the sFlow Analyzer to be added. Up to four entries can
be added.
Users may enter an alphanumeric string of up to 16 characters to define the owner of this
entry. Users are encouraged to give this field a name that will help them identify this entry.
When an entry is made in this field, the following Timeout field is automatically set to 400
seconds, unless the user alters the Timeout field.
This field is used to specify the timeout for the Analyzer Server. When the server times out, all
sFlow samples and counter polls associated with this server will be deleted. The user may set
a time between 1 and 2000000 seconds with a default setting of 400 seconds. Infinite can be
selected to ensure that it never times out.
Click the radio button and enter the IPv4 address of the sFlow Analyzer Server. If this field is
not specified, the entry will become 0.0.0.0 and therefore the entry will be inactive. Users must
set this field.
Click the radio button and enter the IPv6 address of the sFlow Analyzer Server.
The destination UDP port where sFlow datagrams will be sent. The default setting for this field
is 6343.
This field will specify the maximum number of data bytes that can be packaged into a single
sFlow datagram. Users may select a value between 300 and 1400 bytes with a default setting
of 1400 bytes.