Creating A Maintenance Association; Create Maintenance Points; Creating A Maintenance End Point - Dell S4048–ON Configuration Manual

S-series 10gbe switches
Hide thumbs Also See for S4048–ON:
Table of Contents

Advertisement

MA-Name
VLAN
My_MA
200
Domain Name: praveen
Level: 6
Total Service: 1
Services
MA-Name
VLAN
Your_MA
100

Creating a Maintenance Association

A Maintenance association (MA) is a subdivision of an MD that contains all managed entities corresponding to a single end-to-end
service, typically a virtual area network (VLAN).
Create maintenance association.
ECFM DOMAIN mode
service name vlan vlan-id

Create Maintenance Points

Domains are comprised of logical entities called maintenance points. A maintenance point is a interface demarcation that confines
CFM frames to a domain.
There are two types of maintenance points:
Maintenance End Points (MEPs) — a logical entity that marks the end-point of a domain.
Maintenance Intermediate Points (MIPs) — a logical entity configured at a port of a switch that constitutes intermediate
points of an Maintenance Entity (ME). An ME is a point-to-point relationship between two MEPs within a single domain.
These roles define the relationships between all devices so that each device can monitor the layers under its responsibility.

Creating a Maintenance End Point

A maintenance endpoint (MEP) is a logical entity that marks the endpoint of a domain.
There are two types of MEPs defined in 802.1ag for an 802.1 bridge:
Up-MEP — monitors the forwarding path internal to a bridge on the customer or provider edge. On Dell Networking systems,
the internal forwarding path is effectively the switch fabric and forwarding engine.
Down-MEP — monitors the forwarding path external another bridge.
Configure Up- MEPs on ingress ports, that send traffic towards the bridge relay. Configure Down-MEPs on egress ports, that send
traffic away from the bridge relay.
1.
Create an MEP.
INTERFACE mode
ethernet cfm mep {up-mep | down-mep} domain {name | level } ma-name name mepid mep-id
The range is from 1 to 8191.
2.
Display configured MEPs and MIPs.
EXEC Privilege mode
show ethernet cfm maintenance-points local [mep | mip]
Dell#show ethernet cfm maintenance-points local mep
---------------------------------------------------------------
MPID
Domain Name
MA Name
----------------------------------------------------------------
100
cfm0
CC-Int
X-CHK Status
10s
enabled
CC-Int
X-CHK Status
10s
enabled
Level
Type
Port
VLAN
Dir
MAC
7
MEP
Te 4/10
CCM-Status
Enabled
85
802.1ag

Advertisement

Table of Contents
loading

Table of Contents