Corresponding Servopack Monitor Display Function Names; Names - YASKAWA SGD7S-R70A Product Manual

E-7-series ac servo drive e-7s servopack with ft/ex specification for indexing application
Hide thumbs Also See for SGD7S-R70A:
Table of Contents

Advertisement

Menu Bar
Button
Alarm Display
Alarms
Reset Motor Type Alarm
Solutions
Mechanical Analysis
Edit Program Table
Table
Edit ZONE Table
Editing
Edit Jog Speed Table
10.1.2
Corresponding SERVOPACK Monitor Display Function

Names

Menu Bar
Button
Motor Speed [min
Speed Reference [min
Torque Reference [%]
• Rotary Servomotors:
• Linear Servomotors:
• Rotary Servomotors:
Motion
• Linear Servomotors:
Monitor
Input Reference Pulse Speed [min
Position Deviation [reference units]
Accumulated Load Ratio [%]
Regenerative Load Ratio [%]
Dynamic Brake Resistor Power Con-
sumption [%]

10.1.2 Corresponding SERVOPACK Monitor Display Function Names

SigmaWin+
Function Name
SigmaWin+
Name [Unit]
-1
]
-1
]
Rotational Angle 1 [encoder
pulses]
(number of encoder pulses from
origin within one encoder rotation)
Electrical Angle 1 [linear encoder
pulses]
(linear encoder pulses from the
polarity origin)
Rotational Angle 2 [deg]
(electrical angle from origin within
one encoder rotation)
Electrical Angle 2 [deg]
(electrical angle from polarity ori-
gin)
10.1 Corresponding SERVOPACK and SigmaWin+ Function Names
Fn No.
Fn000
Display Alarm History
Fn006
Clear Alarm History
Fn021
Reset Motor Type Alarm
Fn060
Edit/Save Program Table
Fn063
Initialize Program Table
Fn061
Edit/Save ZONE Table
Fn064
Initialize ZONE Table
Fn062
Edit/Save Jog Speed Table
Fn065
Initialize Jog Speed Table
Un No.
Un000
Motor Speed [min
Un001
Speed Reference [min
Torque Reference [%]
Un002
(percentage of rated torque)
• Rotary Servomotors:
Rotational Angle 1 [encoder pulses]
(number of encoder pulses from origin within
one encoder rotation displayed in decimal)
Un003
• Linear Servomotors:
Electrical Angle 1 [linear encoder pulses]
(linear encoder pulses from the polarity origin
displayed in decimal)
• Rotary Servomotors:
Rotational Angle 2 [deg]
(electrical angle from polarity origin)
Un004
• Linear Servomotors:
Electrical Angle 2 [deg]
(electrical angle from polarity origin)
Input Reference Pulse Speed [min
-1
Un007
]
(displayed only during position control)
Position Error Amount [reference units]
Un008
(displayed only during position control)
Accumulated Load Ratio [%]
Un009
(percentage of rated torque: effective torque in
cycles of 10 seconds)
Regenerative Load Ratio [%]
(percentage of processable regenerative
Un00A
power: regenerative power consumption in
cycles of 10 seconds)
Power Consumed by DB Resistance [%]
Un00B
(percentage of processable power at DB acti-
vation: displayed in cycles of 10 seconds)
Continued from previous page.
SERVOPACK
Function Name
SERVOPACK
Name [Unit]
-1
]
-1
]
-1
]
Continued on next page.