8.1 Alarm Displays

8.1.3 INDEXER Alarm Displays and Troubleshooting

8.1.3

INDEXER Alarm Displays and Troubleshooting

INDEXER alarms and corrections for them are given in the following table.
Error
Number
E19A
E1AA
E1BA
E1CA
E1DA
E1EA
8-38
Alarm
Alarm Name
Number
Program Table
Checksum
Alarm
A.EF9
(Detected only
when control
power supply is
turned ON.)
Program Table
Version
Unmatched
A.EF9
(Detected only
when control
power supply is
ON.)
Program Out-
of-range Alarm
(Detected only
A.EF9
when control
power supply is
turned ON.)
ZONE Table
Checksum
Alarm
A.EF9
(Detected only
when control
power supply is
turned ON.)
ZONE Table
Version
Unmatched
A.EF9
(Detected only
when control
power supply is
turned ON.)
ZONE Table
Out-of-range
Alarm
A.EF9
(Detected only
when control
power supply is
turned ON.)
Meaning
Corrective Action
The program table
stored in flash mem-
ory was not
• Initialize the pro-
recorded properly.
(This alarm can
gram table. (Fn063)
• If the problem is not
occur if the control
power supply is
solved, correct the
turned OFF while the
program table.
program table is
being saved or ini-
tialized.)
• Change the firm-
The combination of
ware version.
the firmware version
• Change the pro-
and the program
gram table version
table version is
to match the firm-
wrong.
ware version.
• Change the firm-
A value set in the
ware version.
• Change the pro-
program table is not
within the allowed
gram table version
setting range.
to match the firm-
ware version.
The ZONE table
stored in flash mem-
ory was not
• Initialize the ZONE
recorded properly.
table. (Fn064)
(This alarm can
• If the problem is not
occur if the control
solved, correct the
power supply is
ZONE table.
turned OFF while the
ZONE table is being
saved or initialized.)
• Change the firm-
The combination of
ware version.
• Change the ZONE
the firmware version
and the ZONE table
table version to
version is wrong.
match the firmware
version.
• Change the firm-
A value set in the
ware version.
• Change the ZONE
ZONE table is not
within the allowed
table version to
setting range.
match the firmware
version.
Servo-
motor
Alarm
Stop
Reset
Method
*1
Gr.1
Available
*1
Gr.1
Available
*1
Gr.1
Available
*2
Gr.1
Available
*2
Gr.1
Available
*2
Gr.1
Available
Continued on next page.