Siemens SINAMICS G110D Operating Instructions Manual page 42

Hide thumbs Also See for SINAMICS G110D:
Table of Contents

Advertisement

Connection
4.8 Cables and connections
Table 4- 5
Motor connector
Power
cable
Belcom
rating
size
"DESINA"
Cable No.
0.75 kW
1 mm
13EBN17Z08P
2
18 AWG
1.50 kW
3.00 kW
2.5 mm
13EBN13Z08P
2
14 AWG
4.00 kW
5.50 kW
4 mm
13EBN11Z08P
2
12 or 10
7.50 kW
AWG
4 x crimps are required for each inverter for the motor connections; use 75°C copper wire only
Table 4- 6
Temperature sensor and EM brake
Power
cable
rating
size
0.75 kW
1 mm
2
18 AWG
1.50 kW
3.00 kW
2.5 mm
2
14 AWG
4.00 kW
5.50 kW
4 mm
2
12 or 10
7.50 kW
AWG
2 x crimps are required for each auxiliary signal pair; use 75°C copper wire only
Connection specifications
Table 4- 7
42
All connector parts are Harting Q8/0
Shell
Harting Q8/0
0912 008
3001
Belcom
Temperature sensor pair
"DESINA"
Crimp size
Cable No.
13EBN17Z08P
0.75 mm
20 AWG
13EBN13Z08P
1 mm
2
18 AWG
13EBN11Z08P
1 mm
2
18 AWG
Mains supply and motor output specifications
Mains supply
Pin
Function
1
L1
2
L2
3
L3
4
-
11
-
12
-
PE
Protective Earth
Type
HAN Q4/2 (Male)
Spec.
3AC 380V...500V ±
10%
Crimp
Crimp number
size
1 mm
0933 000 6105
2
18 AWG
2.5 mm
0933 000 6102
2
14 AWG
4 mm
0933 000 6107
2
12 or 10
AWG
Crimp number
0933 000 6114
2
0933 000 6105
0933 000 6105
Operating Instructions, 2009-05-15, A5E02385577A AB
Hood
1912 008 0502
1912 008 0528
EM Brake pair
Crimp size
Crimp number
0.75 mm
0933 000 6114
2
20 AWG
1 mm
0933 000 6105
2
18 AWG
1.5 mm
0933 000 6104
2
18 AWG
Motor output
Pin
Function
1
U
2
Not connected
3
W
4
EM Brake (-)
5
Temperature sensor (+)
6
EM Brake (+)
7
V
8
Temperature sensor (-)
PE
Protective Earth
Type
HAN Q8 (Female)
Spec.
-
Gland/Seal
1912 000 5057
LUTZE 600173
(NOT Harting)
SINAMICS G110D