Step Function; Skip Function; M Code Output Function; Teaching Function - Mitsubishi Electric AJ65BT-D75P2-S3 User Manual

Hide thumbs Also See for AJ65BT-D75P2-S3:

Advertisement

3
SPECIFICATIONS AND FUNCTIONS
Auxiliary function

Step function

Skip function

M code output function

Teaching function

Other functions
Command in-position
function
Stepping motor mode
function
Acceleration/deceleration
process function
Indirectly specification
function

Common functions

Parameter initialization function

Execution data backup function

LED display function

Clock data function

This function temporarily stops the operation to confirm the
positioning operation during debugging, etc.
The operation can be stopped at each "automatic deceleration"
or "positioning data".
This function stops (decelerates to a stop) the positioning being
executed when the skip signal is input, and carries out the next
positioning.
This function issues an auxiliary work (clamp or drill stop, tool
change, etc.) according to the code No. (0 to 32767) set for
each positioning data.
This function stores the address positioned with manual control
into the positioning address having the designated positioning
data No ( Cd.5 ).
At each automatic deceleration, this function calculates the
remaining distance for the D75P2 to reach the positioning stop
position, and when the value is less than the set value, turns
ON the "command in-position signal".
When using another auxiliary work before ending the control,
use this function as a trigger for the auxiliary work.
This function makes settings for using a stepping motor.
This function adjusts the control acceleration/deceleration.
This function specifies indirectly and starts the positioning data
No.
Common functions
The outline of the functions executed as necessary are described below.
(Refer to "SECTION 2" for details on each function.)
This function returns the "setting data" stored in the D75P2
flash ROM to the default values.
The following two methods can be used.
1) Method using sequence program
2) Method using AD75 software package
This functions stores the "setting data", currently being
executed, into the flash ROM.
1) Method using sequence program
2) Method using AD75 software package
This function displays the D75P2 operation state, signal state
and error details on the 17-segment LED on the front of the
main module.
The display details can be changed with the mode switch on
the front of the main module.
This function sets the PLC CPU clock data in the D75P2. This
used for the various history data.
Details
Details
3 - 11
MELSEC-A
Reference
section
12.7.1
12.7.2
12.7.3
12.7.4
12.7.5
12.7.6
12.7.7
12.7.8
Reference
section
13.2
13.3
13.4
13.5