Condition Data Setting Examples - Mitsubishi Electric AJ65BT-D75P2-S3 User Manual

Hide thumbs Also See for AJ65BT-D75P2-S3:

Advertisement

10
ADVANCED POSITIONING CONTROL

10.4.2 Condition data setting examples

The following shows setting examples for "condition data".
(1)
Setting the device ON/OFF as a condition
[Condition] Device "RXn0" (=D75P2 READY) is ON
Da.14 Condition
target
01
: Device X
H
(2)
Setting the numeric value stored in the "buffer memory" as a
condition
[Condition]
The value stored in buffer memory addresses "802, 803" (=" Md.30 Machine
feed value") is "1000" or larger.
Da.14 Condition
target
04
: Buffer memory
H
(2 words)
(3)
Designating the axis and positioning data No. to be
simultaneously started in "simultaneous start"
[Condition]
Simultaneously starting "axis 2 positioning data No.3".
Da.14 Condition
target
05
: Positioning
H
data No.
*1: For the starting axis (axis where positioning start takes place), set the
value to "0000
Da.15
Da.16
Condition
Address
operator
07
: DEV=ON
H
Da.15
Da.16
Condition
Address
operator
 P1
802
03
:
H
Da.15
Da.16
Condition
Address
operator
0A
: Axis 2
H
designation
".
H
10 - 19
MELSEC-A
Da.17
Da.18
Parameter 1
Parameter 2
0
Da.17
Da.18
Parameter 1
Parameter 2
1000
Da.17
Da.18
Parameter 1
Parameter 2
High-order 16
*1
bits "0003
"
H