Hide thumbs Also See for AJ65BT-D75P2-S3:

Advertisement

3
SPECIFICATIONS AND FUNCTIONS

3.7.4 Input/output interface internal circuit

Input/out
-put
External wiring
class
Input
Input
* The terminal connected to the common line may be either positive or negative.
The outline diagram of the internal circuit for the D75P2 external device connection
interface is shown below.
Pin
Internal circuit
No.
Near-point
11
dog signal
Upper limit
12
signal
Lower limit
13
signal
14
Stop signal
Speed/
position
15
changeover
signal
External
16
start signal
35
Common
36
(+)
Manual
9
pulse
generator A
(–)
phase
27
(+)
Manual
10
pulse
generator B
(–)
phase
28
Drive unit
7
READY
In-position
8
signal
26
Common
6
Zero point
signal
24
25
Common
: Wiring is necessary in positioning.
Signal name
• Near-point dog detection signal for a
DOG
machine zero point return
• Signal for the limit switch provided at
the upper limit of the stroke.
FLS
• Also used for the zero point return retry
function.
• Signal for the limit switch provided at
the lower limit of the stroke.
RLS
• Also used for the zero point return retry
function.
• Signal that stops positioning externally
• When stopping positioning, this signal
turns ON in 4ms or more.
STOP
• After this signal has been turned ON,
positioning is not restarted if this signal
is turned from ON to OFF.
• Signal that changes from speed control
CHG
to position control in speed/position
changeover control.
• Signal that performs an external
positioning start/speed change/skip
request.
STRT
• To make an external start valid, keep
this signal ON more than 4ms.
• Set which function will be used in the
detailed parameter.
COM
• Input voltage 24VDC.
PULSER
A+
PULSER
• Terminal to connect a manual pulse
A–
generator.
• Introduced product: MR-HDP01
PULSER
(Mitsubishi Electric make)
B+
PULSER
B–
Signal for judging whether the drive unit
is normal or abnormal.
ON : Drive unit normal. Positioning
READY
control enabled.
OFF : Drive unit abnormal. Positioning
control disabled.
• Enter the in-position signal from the
drive unit.
INPS
• The ON/OFF status can be monitored
with the remote input (RX).
COM
• Input voltage 24VDC.
• Zero point signal for a machine zero
point return.
PG0
• Generally, the zero point signal of a
pulse encoder, etc. is used.
Input voltage 24V/15V/5VDC
PG0 COM
Pin No. 6-25 24V/15VDC
Pin No. 24-25 5VDC
3 - 42
MELSEC-A
: Perform wiring when necessary.
ON/OFF status
Details
External
wiring
Need for
wiring
D75P2
OFF
ON
ON
OFF
(STOP)
ON
OFF
(STOP)
OFF
ON
(STOP)
OFF
ON
OFF
ON
OFF
ON
OFF
ON