Table 4: Logging applications
Application
switchfabric
lag
vlan
ospf
rip
ldap
snmp
policy
cli
stp
atm
wan
threshold
To define a filter that applies to every application, type
Use the
set logging file condition
log file. The following example defines a filter in which QoS messages with a severity level of Critical or
higher are sent to the log file:
set logging file condition qos critical
Use the
set logging session condition
displayed on the terminal screen. The following example defines a filter in which all messages with a
severity level of Warning or higher are displayed on the screen:
set logging session condition all warning
Use the
set logging server condition
the specified Syslog server. In addition to the application and severity level, you must specify the IP
address of the Syslog server to which you want to apply the filter. The following example defines a filter
in which no RIP messages are sent to the Syslog server with the IP address 175.5.16.33:
set logging server condition rip none 175.5.16.33
Administration of the Avaya G350 Media Gateway
June 2004
Description
Switch fabric failures
Link Aggregation package
VLAN package
OSPF routing package
RIP routing package
LDAP client
SNMP agent
Policy package
CLI
Spanning tree package
ATM expansion
WAN plugged-in expansion
RMON alarms
all
instead of the application.
command to create a filter for system messages that are logged to a
command to create a filter for system messages that are
command to create a filter for system messages that are logged to
Configuring logging
Filters and severity levels