Contact Closure Hardware Configuration; Contact Closure Software Configuration - Avaya G350 Administration

Hide thumbs Also See for G350:
Table of Contents

Advertisement

Configuring contact closure

Contact closure hardware configuration

Contact closure hardware configuration
To configure your hardware for contact closure:
1
Connect an Avaya Partner Contact Closure Adjunct to the Contact Closure port on the Avaya
G350 Media Gateway front panel. The Contact Closure port is labeled CC. Use a telephone cable
with standard RJ-11 connectors.
2
A qualified electrician should connect the electrical devices to the relays on the Avaya Partner
Contact Closure Adjunct. For information on contact closure specifications, see Overview of the
Avaya G350 Media Gateway, 555-245-201.

Contact closure software configuration

You can specify the following contact closure modes:
Mode
mgc
manual-trigger
manual-off
To configure the Avaya G350 Media Gateway to activate contact closure when the feature access code is
dialed:
1
Enter the
contact closure to work in relay 1 of the Avaya Partner Contact Closure Adjunct when activated
by the call controller.
set contact-closure admin 10/1:1 call-controller
2
Use the
return to normal after the call controller triggers it. In the following example, the command sets
relay 2 of the Avaya Partner Contact Closure Adjunct to return to normal 5 seconds after the call
controller triggers contact closure in the relay.
set contact-closure pulse-duration 10/1:2 pulse-duration 5
3
To enable the user to return the relay to normal by dialing a feature access code, set the pulse
duration to 0.
To activate contact closure manually, use the
manual-trigger
Partner Contact Closure Adjunct. Contact closure remains active until you deactivate it by using the
contact-closure admin
set contact-closure admin 10/1:1 manual-trigger
126
Description
The MGC controls contact closure. In mgc mode, the user dials
feature access codes to activate and deactivate contact closure.
Activates contact closure for the specified relay.
Deactivates contact closure for the specified relay.
set contact-closure admin
set contact-closure pulse-duration
. In the following example, the command activates contact closure in relay 1 of the Avaya
command with the parameter
command. In the following example, the command sets
command to set the length of time for the relay to
set contact-closure admin
or
manual-off
auto
Administration of the Avaya G350 Media Gateway
command with the parameter
set
.
June 2004