Configuring logging
Filters and severity levels
Table 3, Severity levels,
Table 3: Severity levels
Severity level
Emergency
Alert
Critical
Error
Warning
Notification
Informational
Debugging
To configure a filter that will eliminate all messages for the specified application, type
severity level.
The sinks have the following default severity levels:
Session — warning
Log file — informational
Syslog — warning
Filters are defined per application.
which you can define filters.
Table 4: Logging applications
Application
boot
system
router
config
temp
filesys
fan
supply
security
cascade
qos
54
on page 54 lists the eight available severity levels.
Code
Description
0
System is unusable
1
Immediate action required
2
Critical condition
3
Error condition
4
Warning condition
5
Normal but significant condition
6
Informational message only
7
Message that only appears during debugging
Table 4, Logging applications,
Description
System startup failures
Operating system failures
Core routing system failures
Configuration changes
Temperature messages
File system problem (flash)
Cooling system
Power supply system
Authentication failure
Stack CASCADE mechanism
QoS messages
Administration of the Avaya G350 Media Gateway
instead of a
none
on page 54 lists the applications for
1 of 2