Lenovo BladeCenter HS23 7875 Problem Determination And Service Manual page 266

Blade server
Table of Contents

Advertisement

• See Chapter 3 "Parts listing" on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Description
Error code
215-901-xxx
Aborted the optical drive self test because the
drive media was not detected.
250
BladeCenter HS23 Blade ServerProblem Determination and Service Guide
Action
3. If the component failure remains, see your
BladeCenter documentation for information
about replacing the optical drive (media tray).
4. If the failure remains, collect the data from the
DSA event log ( "Diagnostic tools overview" on
page 78) and send it to IBM Service. For
information about contacting and sending data
to IBM Service, see "Hardware service and
support" on page 267.
1. Insert a new CD or DVD into the drive and wait
for 15 seconds for the media to be recognized;
then, rerun the test. See "Diagnostic tools
overview" on page 78.
2. Make sure that the cable for the optical drive is
securely connected at both ends of the cable
and tighten any loose connections. See your
BladeCenter documentation for information
about the optical drive (media tray).
3. Make sure that the cable for the optical drive is
not damaged and replace the cable if damage is
present. See your BladeCenter documentation
for information about the optical drive (media
tray).
4. Rerun the test. See "Diagnostic tools overview"
on page 78.
5. For additional troubleshooting information, go to
http://www-947.ibm.com/support/entry/portal/
docdisplay?lndocid=MIGR-41559.
6. Rerun the test. See "Diagnostic tools overview"
on page 78.
7. Replace the CD or DVD drive. See your
BladeCenter documentation for information
about replacing the optical drive (media tray).
8. If the failure remains, collect the data from the
DSA event log (see "Diagnostic tools overview"
on page 78) and send it to IBM Service. For
information about contacting and sending data
to IBM Service, see "Hardware service and
support" on page 267.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bladecenter hs23 1929

Table of Contents