• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 "Parts listing" on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Error Code
Event ID
0x80010200
80010202-0701ffff
0x80010200
80010202-0701ffff
Type
Error Message
Error
System board
(SysBrd 5V)
voltage under
critical threshold.
with chassis
Reading: X,
Threshold: Y
Error
System board
(SysBrd 12V)
voltage under
critical threshold.
with chassis
Reading: X,
Threshold: Y
Action
1. Remove all expansion
cards from the blade
server (see
"Removing an I/O
expansion card" on
page 50).
2. Remove all storage
drives from the blade
server (see
"Removing a hot-
swap storage drive"
on page 44).
3. If the error still
occurs, replace the
system-board
assembly (see
"Removing the
system-board
assembly" on page
71 and "Installing the
system-board
assembly" on page
71).
1. If the under voltage
problem is occurring
on all blade servers,
look for other events
in the log related to
power and resolve
those events (see
"Event logs" on page
79).
2. View the event log
provided by the
advanced
management module
for your BladeCenter
unit and resolve any
power related errors
that might be
displayed.
3. If other modules or
blades are logging the
same issue then
check the power
supply for the
BladeCenter unit.
.
107