Lenovo BladeCenter HS23 7875 Problem Determination And Service Manual page 133

Blade server
Table of Contents

Advertisement

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 "Parts listing" on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Error Code
Event ID
0x80070100
80070101-1001ffff
80070101-1002ffff
80070101-1003ffff
80070101-1004ffff
Type
Error Message
Warning
Expansion Module
0 or 2,
temperature
(BPE4_X TMP)
warning [Note: X=
1-4]
Action
1. Check the IBM
support website for
an applicable retain
tip or firmware update
that applies to this
temperature error.
2. Make sure that the
room temperature is
within the operating
specifications (see
"Features and
specifications" on
page 2).
3. Make sure that none
of the air vents on the
BladeCenter unit and
on the blade server
are blocked.
4. Make sure that all of
the fans on the
BladeCenter unit are
running.
5. Make sure that each
bay of the
BladeCenter unit has
either a device or a
filler installed.
6. Make sure that the
blade server is not
missing any heat
sinks, DIMMs, heat-
sink fillers, or DIMM
fillers (see Chapter 3
"Parts listing" on
page 29).
7. View the event logs
provided by the
advanced
management module
for your BladeCenter
unit and resolve any
related errors that
might be displayed.
8. Clear the CMOS data
by removing the
system battery for 30
seconds (see
"Removing the
.
117
Chapter 5
Diagnostics