Lenovo BladeCenter HS23 7875 Problem Determination And Service Manual page 140

Blade server
Table of Contents

Advertisement

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 "Parts listing" on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Error Code
Event ID
0x80070200
80070217-1001ffff
80070217-1002ffff
80070217-1003ffff
80070217-1004ffff
0x80070200
8007021b-0301ffff
8007021b-0302ffff
124
BladeCenter HS23 Blade ServerProblem Determination and Service Guide
Type
Error Message
Error
Expansion Module
0 or 2, Expansion
Card (BPE4_X
Fault) critical
[Note: X=1-4]
Error
Processor X,
interconnect (CPU
X QPILinkErr)
critical [Note: X=
1,2]
Action
1. View the event log
provided by the
advanced
management module
for your BladeCenter
unit and resolve any
expansion card
related errors that
might be displayed.
2. If other modules or
blades are logging the
same issue then
check the power
supply for the
BladeCenter unit.
3. If the error still
occurs, replace the
system-board
assembly (see
"Removing the
system-board
assembly" on page
71 and "Installing the
system-board
assembly" on page
71).
1. Check the IBM
support website for
an applicable retain
tip or firmware update
that applies to this
error.
2. (Trained technician
only) Reseat the
processor (see
"Removing a
microprocessor and
heat sink" on page 61
and "Installing a
microprocessor and
heat sink" on page
65).
3. (Trained technician
only) If the error
continues, replace the
system-board
assembly (see
"Removing the