• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 "Parts listing" on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Diagnostic
Message
code
S.3030007
[S.3030007] A firmware
fault has been detected
in the UEFI image.
S.3040007
[S.3040007] A firmware
fault has been detected
in the UEFI image.
I.3048005
[I.3048005] UEFI has
booted from the backup
flash bank.
W.3048006
[W.3048006] UEFI has
booted from the backup
flash bank due to an
Automatic Boot
Recovery (ABR) event.
S.3050007
[S.3050007] A firmware
fault has been detected
in the UEFI image.
Description
Internal UEFI Firmware
Fault Detected, System
halted.
Internal UEFI Firmware
Fault Detected, System
halted.
Booting Backup UEFI
Image.
Automated Boot
Recovery, Booting
Backup UEFI Image.
Internal UEFI Firmware
Fault Detected, System
halted.
Action
1. Check the IBM support website for an
applicable retain tip or firmware update that
applies to this error.
2. Recover the server firmware (see
"Recovering from a UEFI update failure" on
page 254).
3. (Trained technician only) Replace the system
board (see "Removing the system-board
assembly" on page 71 and "Installing the
system-board assembly" on page 71).
1. Check the IBM support website for an
applicable retain tip or firmware update that
applies to this error.
2. Recover the server firmware (see
"Recovering from a UEFI update failure" on
page 254).
Information only. Set SW1-5 to the on position to
allow the server to boot from the backup UEFI
(see "System-board switch" on page 8).
1. Run the Setup utility (see "Using the Setup
utility" on page 11), select Load Default
Settings, and save the settings.
2. Recover the server firmware (see
"Recovering from a UEFI update failure" on
page 254).
3. (Trained technician only) Replace the system
board (see "Removing the system-board
assembly" on page 71 and "Installing the
system-board assembly" on page 71).
1. Check the IBM support website for an
applicable retain tip or firmware update that
applies to this error.
2. Recover the server firmware (see
"Recovering from a UEFI update failure" on
page 254).
Chapter 5
.
99
Diagnostics