Lenovo BladeCenter HS23 7875 Problem Determination And Service Manual page 190

Blade server
Table of Contents

Advertisement

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 "Parts listing" on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Error Code
Event ID
0x806f0513
806f0513-2582ffff
174
BladeCenter HS23 Blade ServerProblem Determination and Service Guide
Type
Error Message
Error
Group 2, (PCI
express bus 1-2,
Expansion Module
2-0)
• (All PCI Error)
PCI system
error,
Action
8. Replace failing
adapter and reinstall
any other expansion
cards that were
removed (see
"Installing an I/O
expansion card" on
page 53).
9. Replace the
expansion unit (see
"Removing an
optional expansion
unit" on page 58 and
"Installing an optional
expansion unit" on
page 59).
10. If the system contains
multiple
microprocessors,
swap the
microprocessors (see
"Removing a
microprocessor and
heat sink" on page 61
and "Installing a
microprocessor and
heat sink" on page
65).
11. (Trained technician
only) If the error
continues, replace the
system-board
assembly (see
"Removing the
system-board
assembly" on page
71 and "Installing the
system-board
assembly" on page
71).
1. If this blade and/or
any attached cables
were recently
installed, moved,
serviced, or
upgraded, perform
the following steps:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bladecenter hs23 1929

Table of Contents