Lenovo BladeCenter HS23 7875 Problem Determination And Service Manual page 262

Blade server
Table of Contents

Advertisement

• See Chapter 3 "Parts listing" on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Description
Error code
202-801-xxx
Aborted the memory stress test due to an
internal program error.
202-802-xxx
Failed the memory stress test due to
insufficient available memory for testing.
246
BladeCenter HS23 Blade ServerProblem Determination and Service Guide
Action
1. If the blade server has stopped responding, turn
off and restart the blade server; then, rerun the
test. See "Turning off the blade server" on page
7, "Turning on the blade server" on page 6, and
"Diagnostic tools overview" on page 78.
2. Make sure that the DSA Diagnostic code is at
the latest level; then, rerun the test ( "Diagnostic
tools overview" on page 78). The latest code
can be found on the IBM support website at
http://www.ibm.com/ support/entry/portal/
docdisplay? brand=5000008&lndocid=SERV-
DSA.
3. Make sure that the system BIOS firmware is at
the latest level, upgrade if necessary; then, rerun
the test (see "Diagnostic tools overview" on
page 78). The BIOS firmware level can be found
in the DSA Diagnostic Event Log within the
Firmware/VPD section for this component. The
latest level firmware for this component can be
found on the IBM support website at http://
www-933.ibm.com/ support/fixcentral/systemx/
groupView? query.productGroup=ibm%
2FBladeCenter.
4. Rerun the test. See "Diagnostic tools overview"
on page 78.
5. Replaced the failing DIMMs (as indicated by the
diagnostic tool) and rerun the test.
6. If the component failure remains, refer to
Chapter 4 "Removing and replacing blade
server components" on page 37 to replace the
failed component.
1. If the blade server has stopped responding, turn
off and restart the blade server; then, rerun the
test. See "Turning off the blade server" on page
7, "Turning on the blade server" on page 6, and
"Diagnostic tools overview" on page 78.
2. press F1 during start up and in the Setup utility
> Resource Utilization section, click Available
System Memory to re-enable all memory; then,
rerun the test (see "Diagnostic tools overview"
on page 78).
3. Make sure that the system BIOS firmware is at
the latest level, upgrade if necessary; then, rerun
the test (see "Diagnostic tools overview" on
page 78). The BIOS firmware level can be found
in the DSA Diagnostic Event Log within the
Firmware/VPD section for this component. The
latest level firmware for this component can be
found on the IBM support website at http://