• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 "Parts listing" on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Error Code
Event ID
0x80070300
80070302-1001ffff
80070302-1002ffff
80070302-1003ffff
80070302-1004ffff
0x80070400
80070401-0701ffff
130
BladeCenter HS23 Blade ServerProblem Determination and Service Guide
Type
Error Message
Error
Expansion Module
0 or 2, voltage
(BPE4_X VOL)
non-recoverable
[Note: X=1-4]
Warning
System board,
temperature (VRD
Hot) warning
Action
battery" on page 41
and "Installing the
battery" on page 42).
9. Make sure that the
heat sink is properly
attached to the
microprocessor (see
"Installing a
microprocessor and
heat sink" on page
65).
1. If the under voltage
problem is occurring
on all blade servers,
look for other events
in the IMM2 event log
related to power and
resolve those events
(see "Event logs" on
page 79).
2. View the event log
provided by the
advanced
management module
for your BladeCenter
unit and resolve any
power related errors
that might be
displayed.
3. If other modules or
blades are logging the
same issue then
check the system
power supply,
otherwise replace the
Blade PCI Express I/
O expansion unit. See
"Removing an
optional expansion
unit" on page 58 and
"Installing an optional
expansion unit" on
page 59.
1. Make sure that the
room temperature is
within the operating
specifications (see
"Features and

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bladecenter hs23 1929