Description
Error code
210-000-000
Passed the memory self test.
201-811-xxx
Aborted the memory self test because the test
was unable to locate the _SM_ key when
locating the SMBIOS structure data.
201-812-xxx
Aborted the memory self test because the
SMBIOS type 0 structure indicates a non-
supported, invalid machine ID.
238
BladeCenter HS23 Blade ServerProblem Determination and Service Guide
Action
N/A
1. If the blade server has stopped responding, turn
off and restart the blade server; then, rerun the
test. See "Turning off the blade server" on page
7, "Turning on the blade server" on page 6, and
"Diagnostic tools overview" on page 78.
2. Make sure that the system BIOS firmware is at
the latest level, upgrade if necessary; then, rerun
the test ( "Diagnostic tools overview" on page
78). The BIOS firmware level can be found in the
DSA Diagnostic Event Log within the Firmware/
VPD section for this component. The latest level
firmware for this component can be found on
the IBM support website at http://www-933.ibm.
com/ support/fixcentral/systemx/groupView?
query.productGroup=ibm%2FBladeCenter.
3. Rerun the test. See "Diagnostic tools overview"
on page 78.
4. If the component failure remains, refer to
Chapter 4 "Removing and replacing blade
server components" on page 37 to replace the
failed component.
5. Rerun the test.
1. If the blade server has stopped responding, turn
off and restart the blade server; then, rerun the
test. See "Turning off the blade server" on page
7, "Turning on the blade server" on page 6, and
"Diagnostic tools overview" on page 78.
2. Make sure that the system BIOS firmware is at
the latest level, upgrade if necessary; then, rerun
the test ( "Diagnostic tools overview" on page
78). The BIOS firmware level can be found in the
DSA Diagnostic Event Log within the Firmware/
VPD section for this component. The latest level
firmware for this component can be found on
the IBM support website at http://www-933.ibm.
com/ support/fixcentral/systemx/groupView?
query.productGroup=ibm%2FBladeCenter.
3. Rerun the test. See "Diagnostic tools overview"
on page 78.
4. If the component failure remains, refer to
Chapter 4 "Removing and replacing blade
server components" on page 37 to replace the
failed component.