Lenovo BladeCenter HS23 7875 Problem Determination And Service Manual page 138

Blade server
Table of Contents

Advertisement

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 "Parts listing" on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Error Code
Event ID
0x80070200
80070202-0701ffff
0x80070200
80070202-1001ffff
80070202-1002ffff
80070202-1003ffff
80070202-1004ffff
122
BladeCenter HS23 Blade ServerProblem Determination and Service Guide
Type
Error Message
Error
System board,
voltage (SysBrd
Vol Fault) critical
Error
Expansion Module
0 or 2, voltage
(BPE4_X VOL)
critical [Note: X=1-
4]
Action
1. Reseat the blade
server in the
BladeCenter unit (see
"Removing the blade
server from the
BladeCenter unit" on
page 39 and
"Installing the blade
server in a
BladeCenter unit" on
page 39).
2. If the error continues,
replace the system-
board assembly (see
"Removing the
system-board
assembly" on page
71 and "Installing the
system-board
assembly" on page
71).
1. If the under voltage
problem is occurring
on all blade servers,
look for other events
in the IMM2 event log
related to power and
resolve those events
(see "Event logs" on
page 79).
2. View the event log
provided by the
advanced
management module
for your BladeCenter
unit and resolve any
power related errors
that might be
displayed.
3. If other modules or
blades are logging the
same issue then
check the system
power supply,
otherwise replace the
Blade PCI Express I/
O expansion unit. See
"Removing an
optional expansion

Advertisement