Lenovo BladeCenter HS23 7875 Problem Determination And Service Manual page 191

Blade server
Table of Contents

Advertisement

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 "Parts listing" on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Error Code
Event ID
Type
Error Message
• (One of PCI
Error) PCI
system error, or
• (PCIs) PCI
system error
Action
a. Reseat the
adapter and any
attached cables.
b. Reload the device
driver.
c. If the device is not
recognized, re-
configure slot to
Gen1 or Gen2.
d. You can configure
Gen1/Gen2
settings in F1
Setup.
1) Go to System
Settings →
Devices and
I/O Ports →
PCIe Gen1/
Gen2/Gen3
Speed
Selection , or
the ASU
Utility.
2. Check IBM support
website for an
applicable device
driver, firmware
update, pdsg revision
or other information
that applies to this
error.
3. Load new device
driver and any
required firmware
updates.
4. If problem persists,
remove the Adapter
Card. If system
reboots successfully
without the adapter,
replace the card.
5. (Trained technician
only) If the problem
continues, replace the
processor (see
"Removing a
microprocessor and
heat sink" on page 61
.
175
Chapter 5
Diagnostics

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bladecenter hs23 1929

Table of Contents