• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 "Parts listing" on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Error Code
Event ID
0x80010000
80010002-0701ffff
0x80010200
80010202-0701ffff
106
BladeCenter HS23 Blade ServerProblem Determination and Service Guide
Type
Error Message
Warning
System board
(CMOS battery)
voltage under
warning threshold.
with chassis
Reading: X,
Threshold: Y
Error
System board
(CMOS battery)
voltage under
critical threshold.
Reading: X,
Threshold: Y
Action
1. If the machine has
been recently
installed, moved, or
serviced, ensure the
system battery is
properly seated, and
the system battery
polarity is correct.
2. Replace the system
battery (see
"Removing the
battery" on page 41
and "Installing the
battery" on page 42).
1. Remove all expansion
cards from the blade
server (see
"Removing an I/O
expansion card" on
page 50).
2. Remove all storage
drives from the blade
server (see
"Removing a hot-
swap storage drive"
on page 44).
3. If the error still
occurs, replace the
system-board
assembly (see
"Removing the
system-board
assembly" on page
71 and "Installing the
system-board
assembly" on page
71).