Lenovo BladeCenter HS23 7875 Problem Determination And Service Manual page 173

Blade server
Table of Contents

Advertisement

• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 3 "Parts listing" on page 29 to determine which components are consumable, structural, or CRU
parts.
• If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
Error Code
Event ID
0x806f0313
806f0313-1701ffff
Type
Error Message
Error
Chassis (NMI
State) software
NMI
Action
"Removing the
system-board
assembly" on page
71 and "Installing the
system-board
assembly" on page
71).
6. (Trained technician
only) Remove the
affected
microprocessor and
check the
microprocessor
socket pins for any
damaged pins. If a
damage is found,
replace the system-
board assembly (see
"Removing the
system-board
assembly" on page
71 and "Installing the
system-board
assembly" on page
71).
7. (Trained technician
only) Replace the
affected
microprocessor (see
"Removing a
microprocessor and
heat sink" on page 61
and "Installing a
microprocessor and
heat sink" on page
65).
1. Verify that you have
the latest system
firmware (see
"Updating firmware
and device drivers"
on page 23).
2. If an expansion card
is installed in the
blade server, verify
that the firmware for
each expansion card
is up to date.
.
157
Chapter 5
Diagnostics